If a specific post was interesting or useful to you, we recommend that you Like that post. It tells the post author, and others, that you found the information valuable. Clicking Like is another way to let others know that you enjoy it without leaving a comment.
Log in to join the conversation and Like this content.
|
|
|
|
3dit0r (Dec 13th 2024) |
|
Total Likes: 1 |
|
Re: HD621 BNC Comms
#316982
Dec 13th a 05:55 PM
|
| by Carl |
| Carl |
Type 5 or 6 is only when use a multi channel controller ie G68 / 861 etc. The HD621, whilst supporting multiple channels is not a multi channel controller.
Type 1 is the correct initial configuration for a pair of DSP’s in a 2 channel configuration. Then they should be customised as required.
In the case of using them with a just a HD621 (which is not a controller), they should be set to controller = Automatic or Yes.
|
|
|