Originally posted by MTAT:
I think you will find it is settings as I said Meridan UK told me that.
BAD CODE COMBINATION is firmware issue wrong DSP code.
and
Bad EEPROM CONTENTS is wrong settings file in product.
the oly way to get rid of the 2nd is re-type and then make new settings file with the correct config program dependant on the version of software.
As the 2nd was my issue a retype fixed things then making a new settings file with the correct program worked.
To check what version sotware running in 861 press display in standby.
If 4.2 you need to use Mconfig.
If 4.1 and below you need to use legacy configuration program.
Use Legacy on a 4.2 machine you get "Bad eeprom contents"
cheers
Michael
Thanks John and thanks MTAT and everyone else including Mr.Meridian.
You all say retype,...How do I do that. I went to the manual book and they have Legacy Config program as a guide I just followed the manual.
Now can someone tell me how do I "RETYPE".
I am still half way there.
My unit is 4.2 and according to the manual which is written for Legacy config screwed things up for me.