Robert, thank you for your input.

My reference to the wiki was in relation to the pin-outs of a comms lead - I full appreciate that the Reviver is not detailed there.

I didn't suggest at all that the Reviver was not working for any of your other Customers who have a MS200, it was the fact that it does work for everyone else that I posted here in the hope that fellow members maybe able to shed some light on what I may have done incorrectly.

My wiring is pretty standard as far as I am aware - Comms DIN from G68 to Master 3100 (M5 lead), Comms DIN out from Master 3100 to Slave 3100 (S5 lead), Comms DIN out from Slave 3100 to Slave Centre 3100 (S5 lead). I also eliminated any issues with the existing wiring by unplugging the S5 from the Master 3100 as one of my tests - so only the Reviver Comms were connected.

As you say it is a used item and for whatever reason disconnecting pin 1 has made it work - for which I am grateful. The s/n is 14-0169 if that is of any assistance.

Oh and Ian and I may have got to the bottom of the BNC comms issue too.

Nick


Sources: Auralic Aries G1 & Re-plinthed Thorens TD-150/ISOkinetik Power Supply/Linn Ittok/AT33PTG/Trichord Dino
Speakers: DSP3100