Joined: Oct 2009
Posts: 138
Hitchhiker
|
|
Hitchhiker
Joined: Oct 2009
Posts: 138 |
Hi,
I want to trigger my 558 (to bring the multi channel power amplifier out of standby) with the 568.2MM. The 558 has a trigger input (AC or DC signal of between 5 and 30V), but as you might know the 568 has no trigger output.
I know there is a 110V solution which you connect between the power plug (which goes into the 568) of the 568 and the 568 unit, but I prefer a straight 'power path' without extra connections.
Are there any 220V based solutions which for instance use a COMMS or video output (composite, s-video) from the 568?
Thanks in advance for your help!
Cheers, Bob
861v4/ID40/LPSU, G55, HD621, 504 Wilson Benesch Square Five front, Square Centre & Square Two rear, Velodyne SPL-1200 Ultra Mac mini, QNAP TS-219P II, Apple TV 4K, Marantz UD8004, Pioneer Kuro 500M isf NBS Monitor IV cables
|
|
|
|
|
Joined: Sep 2006
Posts: 141
Hitchhiker
|
|
Hitchhiker
Joined: Sep 2006
Posts: 141 |
Hi Bob
A 562v will trigger your 558, check (Duncan's Meridian Info) at the top of the page.
Mike
#1: 861v4, HD621, DSP7000, 2xDSP5000, DSP3300,2xAC12, 218, 504, 508, 518, 562V, Oppo-83,DRM-SB880,DMP-900-4K, SKY Q 2TB, ZD9-4K 65", HUMAX HDR-1000 & HDR110 1TB. #2: 562, 604, Oppo 983, M20s #3: 602, 541, 204, 263, HD 650 Sennheiser #4: 208,518, 563 M3s
|
|
|
|
|
Joined: Oct 2009
Posts: 138
Hitchhiker
|
|
Hitchhiker
Joined: Oct 2009
Posts: 138 |
Hello Mike,
Thanks for the info.
I know the 562v will do the trick, but I hope there is a more simple & compact (!) alternative available.
Regards, Bob
861v4/ID40/LPSU, G55, HD621, 504 Wilson Benesch Square Five front, Square Centre & Square Two rear, Velodyne SPL-1200 Ultra Mac mini, QNAP TS-219P II, Apple TV 4K, Marantz UD8004, Pioneer Kuro 500M isf NBS Monitor IV cables
|
|
|
|
|
Joined: Oct 2008
Posts: 198 Likes: 1
Hitchhiker
|
|
Hitchhiker
Joined: Oct 2008
Posts: 198 Likes: 1 |
I'm also looking for a neat solution to this without having to add a 562.
does the serial port output a voltage?, but I guess this would be present in standby as well.
Main: 861v4, UHD722, 558, Klipschorn, SVS PC13u second: Tom Evans Eikos, DCB1-pre, DIY Nelson Pass PLH amp, DIY speakers.
|
|
|
|
|
Joined: Nov 2006
Posts: 4,013 Likes: 1
Vogon Civil Servant
|
|
Vogon Civil Servant
Joined: Nov 2006
Posts: 4,013 Likes: 1 |
I wonder whether Shawn could do something with his Universal Translator 2. The RS232 voltage ought to be enough for a trigger.
Sooloos, Roon, G series (with LPS upgrade), 800 series (with LPS upgrade), HD621, AC200, Prime and PS, DSPs old and new.
Purdeys, Moke, Leica, 'Blad. Only the best.
|
|
|
|
|
Joined: Oct 2009
Posts: 138
Hitchhiker
|
|
Hitchhiker
Joined: Oct 2009
Posts: 138 |
Where can I find info regarding Shawn's Universal Translator 2? Is it 220V compatible?
Cheers, Bob
861v4/ID40/LPSU, G55, HD621, 504 Wilson Benesch Square Five front, Square Centre & Square Two rear, Velodyne SPL-1200 Ultra Mac mini, QNAP TS-219P II, Apple TV 4K, Marantz UD8004, Pioneer Kuro 500M isf NBS Monitor IV cables
|
|
|
|
|
Joined: Apr 2004
Posts: 12,733 Likes: 88
Don't Panic!
|
|
Don't Panic!
Joined: Apr 2004
Posts: 12,733 Likes: 88 |
Where can I find info regarding Shawn's Universal Translator 2? Is it 220V compatible? From an email from Shawn: The UT itself runs on anything from 7-12vDC (internally regulated) So basically, you want an external 9v power supply.
|
|
|
|
|
Joined: Aug 2007
Posts: 341
Hitchhiker
|
|
Hitchhiker
Joined: Aug 2007
Posts: 341 |
"I wonder whether Shawn could do something with his Universal Translator 2. The RS232 voltage ought to be enough for a trigger."
RS232 is +/- 12 volt. However I don't think I could really do anything with a standard UT to help here as I don't directly assert flow control. I haven't seen any audio device that uses it. On both ends of the UT it just loops RTS/CTS/DSR back to the same device so if a device ended up looking for flow control it would get it.
Shawn
.
|
|
|
|
|
Joined: Oct 2009
Posts: 138
Hitchhiker
|
|
Hitchhiker
Joined: Oct 2009
Posts: 138 |
So the conclusion is that the Universal Translator 2 has no use for triggering a 558 and bring it automatically out of standby?
And if so, are there any alternatives (besides getting a 562v2)?
Cheers, Bob
861v4/ID40/LPSU, G55, HD621, 504 Wilson Benesch Square Five front, Square Centre & Square Two rear, Velodyne SPL-1200 Ultra Mac mini, QNAP TS-219P II, Apple TV 4K, Marantz UD8004, Pioneer Kuro 500M isf NBS Monitor IV cables
|
|
|
|
|
Joined: Feb 2010
Posts: 2,165 Likes: 67
Meridian Partner Senior Shouting Officer
|
|
Meridian Partner Senior Shouting Officer
Joined: Feb 2010
Posts: 2,165 Likes: 67 |
Bob,
We could program you up a second hand AMX controller to plug into the RS232 port on the 568, detect when the 568 has a source selected using its RS232 output (so we know its been turned on) and then flick one of its internal relays to provide you a 12 volt trigger for the 558. Turning this relay back off when the 568 goes into standby. You have another box and PSU(The Axcent 3 and its PSU) which you have to put somewhere, but you don't need to get at it for it to work. It's a bit overkill but it's an option.. cost shipped would be about �250.
Rick
|
|
|
|
|
Joined: Oct 2009
Posts: 138
Hitchhiker
|
|
Hitchhiker
Joined: Oct 2009
Posts: 138 |
Hi Rick,
Thanks for the info!
I get the feeling there are no compact & cheaper alternatives available.
Cheers, Bob
861v4/ID40/LPSU, G55, HD621, 504 Wilson Benesch Square Five front, Square Centre & Square Two rear, Velodyne SPL-1200 Ultra Mac mini, QNAP TS-219P II, Apple TV 4K, Marantz UD8004, Pioneer Kuro 500M isf NBS Monitor IV cables
|
|
|
|