Hi Mauro
That's a kind offer, you're a Gentleman!

Do you have the 5000s connected to your G68 or G91 at present? If so, you need to press Fn + < or > to accesss the menu items you want. The G68 and G91 will most likely be set as the system Controller from when you last used them, as that's standard practice.
It's a long time since I ran a pair of DSPs without a controller so I can't remember what they display as you scroll through in Standby, but I'll check with my 5000s later.
In the meantime it's worth checking the comms status of everything connected by doing the following, assuming you have DSPs and processor wired up with standard Meridian Master and Slave digital/comms cables:
Put the whole system in Standby.
Point MSR(+) at the processor, and press Clear.
- The processor display should read "Controller" and your Master DSP "N.Con" (mine is a dot matrix version, the older 7 segment LED display version may read slightly differently)
Now select a source to bring system out of Standby. Point MSR(+) at the processor and use Fn < > to access the menu. These choices are made on the processor, not the DSP.
I should also say that when the DSPs are initially set up by pointing the remote at the display in Standby (and have them disconnected from the G68/G91 to do this) you can select a Controller Status of Yes, No or Auto. For the above steps to work, you need to have selected Auto. If you do otherwise, you are instructing the DSP to either be it's own Controller (or Not) and it will ignore comms signals from the processor.
Cheers
George