Seems you have been trying a bit, with some great (moral) support here, but still no progress. Usually Meridian support is quite responsive. Have you shot them an email?
This was the response I received when I last attempted to solve the problem. I have tried all of the suggestions except for measuring the output voltage from the power supply.
Version 1.40 is the latest firmware for the speakers, so it not that. Not that it should affect things, but is the 861 up to date in regard to firmware?
In the absence of a firm theory of why the 861 is power-cycling in this way, we can suggest a few things to try…
1. We would try changing the 861 config file so that a different source is selected when Room Correction is started. We don’t have a known issue with the Sooloos card being the “start-up” source, but we try something else as an experiment. Maybe just create a CD source in the program so the system switches to this when the process begins.
2. Also, within your config file… Is there any particular reason why you have the Sooloos System is linked via the Radio source? Again, this is not a known problem, but it’s not the standard way to connect Sooloos. We would normally connect the Sooloos system directly from its “Net” output to the “Net” input on the 861. The Sooloos source can be assigned to whichever MSR key you prefer, but by default we use “Aux” with the legend entered as “SLS”. It seems unlikely that this the source of the problem, but my “Meridian OCD” kicks in any unconventional arrangement.
3. Next, is it possible to try a different Master speaker? The Master is the point of communication between the 861 and the speakers, so it may be worthwhile checking a different set of hardware. If the cables are installed such that you can’t move the 5M lead, you could temporarily move either the left or right speakers to the centre position.
4. Another possible explanation is that the behaviour is the earliest manifestation of a fault on the 861’s PSU. As the unit is switching to carry out Room Correction, the slight surge in current required is pushing the PSU beyond its capabilities. The 861 has a supervisor circuit which senses any dips in internal voltage and protects the unit by switching off its power.
Please let us know what you find – we’re really keen to help you resolve this.
Regards, Des.
Des Ford
Customer Support Manager
Meridian Audio Ltd